Important Notice

The $n \cdot \sigma$ cut used to delete clusters is heavily process-dependent and must be tuned for yourselves. The cut values can be different for electromagnetic and hadronic clusters and are stored in COMMON /CMBCUT/ as separate cut variables: ENSGEM for electromagnetic and ENSGHD for hadronic clusters. These cut values can be set by a block data:

      BLOCK DATA CMBBLK

      COMMON /CMBCUT/ ADXECT, ENSGEM, ENSGHD
      REAL*4          ADXECT, ENSGEM, ENSGHD

      DATA ADXECT /    20.0 /
C--
C  ENSGEM = n for EM-clusters 
C--
      DATA ENSGEM /     2.0 /
C--
C  ENSGHD = n for HD-clusters 
C--
      DATA ENSGHD /     2.0 /
      END