next up previous
Next: New formula for hadron Up: Calorimeter hit signal and Previous: Calorimeter hit signal and

Lateral spread

Lateral spread of signals in Elemag and Hadron calorimeter is generated assuming the following formula.


 \begin{displaymath}
F(x)=a_1 \exp^{-\vert x\vert/b_1} + a_2 \exp^{-\vert x\vert/b_2}
\end{displaymath} (1)

where, a1, a2, b1, b2 are parameters which characterize the lateral spread of signals in calorimeters. In the Quick Simulator, they are defined in the subroutine smrshw. They are show in the table below.
 
Table 1: Standard parameter for shower shape generation.
  Elemag Calorimeter Hadron Calorimeter
a1 0.07/1.263 1.0/11.40
b1 0.45 2.20
a2 0.50/1.263 0.50/11.40
b2 1.20 7.00



akiya miyamoto
2000-01-21