- [ previous  ] - 
  [ top  ] - 
  [ next  ] - 
5.4 CALORIMETER R&Ds
 Requirements
Requirements
   - Single-particle energy resolution for hadrons be 
            better than 40  
 
- Single-particle energy resolution for EM particles be
            better than 15  
 
- Very fine granularity ( be verified by full-simulation) 
 
 
- Hermetic structure
 
 
- Timing resolution of 1 - 2ns to avoid event overlapping
 
 
- Resonable radiation hardness.
Algorithm
   -  Reconstruct single-particle clusters even for closely-located showers. 
        (Granularity)
 
 
-  Assign correct energy for every reconstructed cluster. 
        (Energy Resolution)
 
 
-  Delete clusters which are generated by BG photons as shower albedos.
 
 
-  Delete clusters which are generated by charged particles.
 Cluster & Delete is the best way to account for fluctuation,
 even though correct clustering is challengingly difficult for hadrons.
 
?   Can we dissolve overlapping showers with extremely-fine granularity ?
Design
       Hardware-compensating Tile/Fiber calorimeter (with lead and plastic scintillator)
Options
 
 See Matsunaga-san's talk for detail.
 See Matsunaga-san's talk for detail.
- [ previous  ] - 
  [ top  ] - 
  [ next  ] - 
yoshiaki.fujii@kek.jp, July 10, 2002 at 5th ACFA LCWS at Tokyo