Package List as of July 28, 2003
- All the materials to send to DESY must be once trasported to KEK,
and re-packed as below by following responsible persons.
When we send them back to Japan (to KEK),
they must be packed in exactly the same manner as below.
- Boxes to be used are 40cm x 60cm x 50cm(H)
double-walled corrugated cardboard box.
- Things which we want to borrow at DESY are indicated
so (@DESY).
- If listed devices are confirmed that we can borrow from DESY,
they will be dropped from the list.
- COCOM-related devices are listed in bold faces.
We already have proofs for Hoshin C008 and C021,
Techno C-TS301 and C-TS 102, CAEN C205N.
Things which can be borrowed from ZEUS-Japan.
Confirmed on July-8th and Final
- Low-voltage DC power supply x 3 (Suitable for both DC and APD)
- Step-down voltage transformer x 2 (240V->100V, 1kW)
- Synchroscope Tektronix TDS5104 x 1
- Circuit Tester x 2
- General Tool-kits
Things which can be borrowed from Korbel's group. (Final answer on July 16.)
Fujii will visit DESY on Aug.11th to confirm that following
equipments are suitable for our purposes.
- DAQ-PC (detail of DAQ-program unknown yet)
- PC-CAMAC interface
- CAMAC crate (has 3~4 empty)
- NIM crates (has 3~4 empty slots)
- Signal Cables for T1,T2 (17m x 4)
; Use Korbel's trigger cable. ( We may bring our 10m-long cables.)
- Signal cables for DC (30m x 4) ; Use Korbel's signal cable.
- Signal Cables for KSMX (30m x 40) ; Use Korbel's signal cable.
- Signal Cables for SSMX (30m x 32) ; Use Korbel's signal cable.
- CAMAC ADC 2249A (12ch x 7 = 84ch) (We may bring our 12-bit ADC.)
- CAMAC TDC for ToF measurement (Model# unknown yet)
- Chamber Gas Ar/ethane (50/50)
- HV supply for DCs (+3.0kV x 4ch and -3.0kV x 4ch,
SHV or MHV unknown yet.)
- HV supply for PMTs (1.5kV x 4ch for T1,2 and 1.0kV x 4ch for KSMX,
SHV or MHV unknown yet.)
- Low-voltage DC power supply x 4 (Suitable for both DC and APD)
- Synchroscope x 2 (Model# unknown yet)
- Multimeter x 4 (Model# unknown yet)
- Transit, Theodolite, Tripods (Model# unknown yet)
- Short Lemo-cables and connectors for logic connection
(We may bring some of our own.)
- General Tool-kits (We may bring some of our own.)
Shinshu Packages (SSMX and related) ; responsibility by Takeshita
Box#1
- SSMX assembled with S8664-55.
- PreAmp Box (assembled)
- CAMAC 16ch PH-ADC x 2 ; Hoshin C0008, ser# 19423, 5297
- Cables between SSMX and PreAmp, DC supply
- HV supply (2kV x 32ch) x 1 will be put in KEK packages.
- HV-Lemo Cables for SSMX (20?m) x 32 will be put in KEK packages.
- Signal Cables for SSMX (20?m) x 32 would be put in KEK packages. (@DESY?)
Following equipments can be borrowed from Korbel's group.
- DC Power Supply (+-12V, 2A) x 2
- Tester x 1
- Synchroscope x 1
Kobe Packages (KSMX, T1, T2 and related) ; responsibility by Kawagoe
Box#1
- KSMX (assembled)
- PMT H6568-10 x 4
- Fiber assembly x ?
- Connector Panel
Box#2
- T1(3cm x 3cm) and T2(5cm x 6cm?) , assembled with PMT R3082ASSY
Dr.Korbel has two finger counters of 2mm-width.
This can be used as a tagger (not a trigger) for DC calibration.
- CAMAC 12ch-ADC LRS 2249W x 2 will be brought.
CAEN CIA C205 (32ch) x 2 could be a back-up. (twist-pair input)
CAMAC 16ch-ADC Phillips 7166 x 3 may not be brought.
Dr.Korbel has 200ch of 2249A.(@DESY)
- NIM analog divider x 4ch (for T1,2) will be packed in KEK package.
Following cables would be put in KEK packages. (@DESY?)
- HV-Lemo Cables for KSMX (20?m) x 4 will be put in KEK packages.
- SHV Cables for T1,T2 (20?m) x 4 will be put in KEK packages.
- Signal Cables for KSMX (??m) x 40 would be put in KEK packages. (@DESY?)
- Lemo Cables for T1,T2 (??m) x 4 would be put in KEK packages. (@DESY?)
Following equipments can be borrowed from Korbel's group.
- HV supply (1kV x 4ch) x 1 would be put in KEK packages. (@DESY?)
- CAMAC TDC x 4ch for T1,T2
- Tester x 1
- HV supply (1.5kV x 4ch)
Tsukuba Packages (DC and related) ; responsibility by Ono
Box#1
- Drift Chambers (x,y) x 2
- Gas Regulator with a flow meter either for Ar/ethane or P10.
(@DESY)
- Synflex Tube (30?m) (@DESY)
- Gas Connectors (@DESY)
- Wrench for Gas Cylinder and connectors (@DESY)
- CAMAC TDC Hoshin C021mod.
( LRS3377 needs serious modification of their DAQ program.)
- SHV cables (20?m x 8) will be put in KEK packages.
- Lemo cables (??m x 4) would be put in KEK packages. (@DESY?)
Following equipments can be borrowed from Korbel's group.
- Gas will be provided by DESY.
- NIM HV supplies ; +3kV x 4ch, -3kV x 4ch
- DC Power Supply (+6.5V x 1, -6.5V x 1)
- Tester x 2
KEK Packages (cables, HV supplies, and misc.) ; responsibility by Fujii
Box#1 ; Cable Box.
Dr.Korbel has 17m-trigger cables and 150 of 30m-signal cables.
Difference of the lengths seems too small.
So add 31ns-VDs on.
- HV-Lemo Cables for KSMX (20m?) x 4
- HV-Lemo Cables for SSMX (20m?) x 32
- SHV Cables for T1,T2 (20?m) x 4
- SHV Cables for DC (20?m x 8)
- Short Lemo cables for logic connection ; Borrow from Korbel's group
- Signal Cables for T1,T2 (17m x 4) ; Use Korbel's trigger cable.
- Signal cables for DC (30m x 4) ; Use Korbel's signal cable.
- Signal Cables for KSMX (30m x 40) ;
Use Korbel's signal cable + variable delay (31ns-max)
- Signal Cables for SSMX (30m x 32) ;
Use Korbel's signal cable + variable delay (31ns-max)
Box#2 ; HV+Miscellaneous Box.
- HV supply (2kV x 32ch) x 1 for SSMX ; REPIC-RPH-32010. HV-Lemo connector.
- tape, gloves, etc.
Box#3 ; Variable-Delay Box.
- 31ns Dual Variable Delay x 20
Box#4 ; Variable-Delay Box.
- 31ns Dual Variable Delay x 20
DAQ and PC
These are definitely needed, but hard to send.
Therefore we will use Korbel's system. Fujii will check it on Aug.11th
- PC
- PC-CAMAC interface (both PC-board and C/C)
- CAMAC crate
- NIM crates
Return to the main index.