Package List as of July 28, 2003




Things which can be borrowed from ZEUS-Japan. Confirmed on July-8th and Final
  1. Low-voltage DC power supply x 3 (Suitable for both DC and APD)
  2. Step-down voltage transformer x 2 (240V->100V, 1kW)
  3. Synchroscope Tektronix TDS5104 x 1
  4. Circuit Tester x 2
  5. General Tool-kits
Things which can be borrowed from Korbel's group. (Final answer on July 16.)
Fujii will visit DESY on Aug.11th to confirm that following equipments are suitable for our purposes.
  1. DAQ-PC (detail of DAQ-program unknown yet)
  2. PC-CAMAC interface
  3. CAMAC crate (has 3~4 empty)
  4. NIM crates (has 3~4 empty slots)
  5. Signal Cables for T1,T2 (17m x 4) ; Use Korbel's trigger cable. ( We may bring our 10m-long cables.)
  6. Signal cables for DC (30m x 4) ; Use Korbel's signal cable.
  7. Signal Cables for KSMX (30m x 40) ; Use Korbel's signal cable.
  8. Signal Cables for SSMX (30m x 32) ; Use Korbel's signal cable.
  9. CAMAC ADC 2249A (12ch x 7 = 84ch) (We may bring our 12-bit ADC.)
  10. CAMAC TDC for ToF measurement (Model# unknown yet)
  11. Chamber Gas Ar/ethane (50/50)
  12. HV supply for DCs (+3.0kV x 4ch and -3.0kV x 4ch, SHV or MHV unknown yet.)
  13. HV supply for PMTs (1.5kV x 4ch for T1,2 and 1.0kV x 4ch for KSMX, SHV or MHV unknown yet.)
  14. Low-voltage DC power supply x 4 (Suitable for both DC and APD)
  15. Synchroscope x 2 (Model# unknown yet)
  16. Multimeter x 4 (Model# unknown yet)
  17. Transit, Theodolite, Tripods (Model# unknown yet)
  18. Short Lemo-cables and connectors for logic connection (We may bring some of our own.)
  19. General Tool-kits (We may bring some of our own.)

Shinshu Packages (SSMX and related) ; responsibility by Takeshita

Box#1
  1. SSMX assembled with S8664-55.
  2. PreAmp Box (assembled)
  3. CAMAC 16ch PH-ADC x 2 ; Hoshin C0008, ser# 19423, 5297
  4. Cables between SSMX and PreAmp, DC supply

  5. HV supply (2kV x 32ch) x 1 will be put in KEK packages.
  6. HV-Lemo Cables for SSMX (20?m) x 32 will be put in KEK packages.

  7. Signal Cables for SSMX (20?m) x 32 would be put in KEK packages. (@DESY?)
Following equipments can be borrowed from Korbel's group.
Kobe Packages (KSMX, T1, T2 and related) ; responsibility by Kawagoe

Box#1
  1. KSMX (assembled)
  2. PMT H6568-10 x 4
  3. Fiber assembly x ?
  4. Connector Panel

Box#2
  1. T1(3cm x 3cm) and T2(5cm x 6cm?) , assembled with PMT R3082ASSY
    Dr.Korbel has two finger counters of 2mm-width. This can be used as a tagger (not a trigger) for DC calibration.
  2. CAMAC 12ch-ADC LRS 2249W x 2 will be brought.
    CAEN CIA C205 (32ch) x 2 could be a back-up. (twist-pair input)
    CAMAC 16ch-ADC Phillips 7166 x 3 may not be brought.
    Dr.Korbel has 200ch of 2249A.(@DESY?)
  3. NIM analog divider x 4ch (for T1,2) will be packed in KEK package.
Following cables would be put in KEK packages. (@DESY?) Following equipments can be borrowed from Korbel's group.
Tsukuba Packages (DC and related) ; responsibility by Ono

Box#1
  1. Drift Chambers (x,y) x 2
  2. Gas Regulator with a flow meter either for Ar/ethane or P10. (@DESY?)
  3. Synflex Tube (30?m) (@DESY?)
  4. Gas Connectors (@DESY?)
  5. Wrench for Gas Cylinder and connectors (@DESY?)
  6. CAMAC TDC Hoshin C021mod. ( LRS3377 needs serious modification of their DAQ program.)

  7. SHV cables (20?m x 8) will be put in KEK packages.

  8. Lemo cables (??m x 4) would be put in KEK packages. (@DESY?)
Following equipments can be borrowed from Korbel's group.
KEK Packages (cables, HV supplies, and misc.) ; responsibility by Fujii

Box#1 ; Cable Box.

Dr.Korbel has 17m-trigger cables and 150 of 30m-signal cables. Difference of the lengths seems too small. So add 31ns-VDs on.
  1. HV-Lemo Cables for KSMX (20m?) x 4
  2. HV-Lemo Cables for SSMX (20m?) x 32
  3. SHV Cables for T1,T2 (20?m) x 4
  4. SHV Cables for DC (20?m x 8)

  5. Short Lemo cables for logic connection ; Borrow from Korbel's group
  6. Signal Cables for T1,T2 (17m x 4) ; Use Korbel's trigger cable.
  7. Signal cables for DC (30m x 4) ; Use Korbel's signal cable.
  8. Signal Cables for KSMX (30m x 40) ; Use Korbel's signal cable + variable delay (31ns-max)
  9. Signal Cables for SSMX (30m x 32) ; Use Korbel's signal cable + variable delay (31ns-max)
Box#2 ; HV+Miscellaneous Box.

  1. HV supply (2kV x 32ch) x 1 for SSMX ; REPIC-RPH-32010. HV-Lemo connector.
  2. tape, gloves, etc.
Box#3 ; Variable-Delay Box.

  1. 31ns Dual Variable Delay x 20
Box#4 ; Variable-Delay Box.

  1. 31ns Dual Variable Delay x 20

DAQ and PC

These are definitely needed, but hard to send. Therefore we will use Korbel's system. Fujii will check it on Aug.11th

  1. PC
  2. PC-CAMAC interface (both PC-board and C/C)
  3. CAMAC crate
  4. NIM crates

Return to the main index.