run number is 0861. ---------- comments ---------- Pos scan anormally.X=22.8cm Y=65.0cm ------------------------------ Beam run. Start date is 990926,and time is 233113. Trigger selection is off. Suppressing mode is off Trigger mask system is off. defined number of particle events are 20000 End date is 990926,and time is 233529. Number of all events are 28146. overall rate is 109.945312 Hz. Number of trigger 0 event are 19874.rate is 77.632812 Hz. Number of trigger 1 event are 0.rate is 0.000000 Hz. Number of trigger 2 event are 0.rate is 0.000000 Hz. Number of trigger 3 event are 126.rate is 0.492188 Hz. Number of trigger 4 event are 77.rate is 0.300781 Hz. Number of trigger 5 event are 3779.rate is 14.761719 Hz. Number of trigger 6 event are 3988.rate is 15.578125 Hz. Number of trigger 7 event are 302.rate is 1.179688 Hz. Number of trigger 8 event are 0.rate is 0.000000 Hz. Number of trigger 9 event are 0.rate is 0.000000 Hz. Number of trigger 10 event are 0.rate is 0.000000 Hz. Number of trigger 11 event are 0.rate is 0.000000 Hz. ******** Scaler Info. ******** T4T5 30852 T4T5TM 7326 Mu Matrix 352