run number is 0622. ---------- comments ---------- Check for Preshower. ------------------------------ Beam run. Start date is 990924,and time is 043839. Trigger selection is off. Suppressing mode is off Trigger mask system is off. defined number of particle events are 10000 End date is 990924,and time is 044013. Number of all events are 14837. overall rate is 157.840426 Hz. Number of trigger 0 event are 9786.rate is 104.106383 Hz. Number of trigger 1 event are 0.rate is 0.000000 Hz. Number of trigger 2 event are 0.rate is 0.000000 Hz. Number of trigger 3 event are 214.rate is 2.276596 Hz. Number of trigger 4 event are 289.rate is 3.074468 Hz. Number of trigger 5 event are 3461.rate is 36.819149 Hz. Number of trigger 6 event are 1016.rate is 10.808511 Hz. Number of trigger 7 event are 71.rate is 0.755319 Hz. Number of trigger 8 event are 0.rate is 0.000000 Hz. Number of trigger 9 event are 0.rate is 0.000000 Hz. Number of trigger 10 event are 0.rate is 0.000000 Hz. Number of trigger 11 event are 0.rate is 0.000000 Hz. ******** Scaler Info. ******** T4T5 16379 T4T5TM 12922 Mu Matrix 11306