run number is 0520. ---------- comments ---------- 100 gev electron energy scan ------------------------------ Beam run. Start date is 990919,and time is 184915. Trigger selection is off. Suppressing mode is on. Trigger mask system is off. defined number of particle events are 5000 End date is 990919,and time is 193134. Number of all events are 12568. overall rate is 4.949980 Hz. Number of trigger 0 event are 4792.rate is 1.887357 Hz. Number of trigger 1 event are 0.rate is 0.000000 Hz. Number of trigger 2 event are 0.rate is 0.000000 Hz. Number of trigger 3 event are 208.rate is 0.081922 Hz. Number of trigger 4 event are 857.rate is 0.337534 Hz. Number of trigger 5 event are 558.rate is 0.219772 Hz. Number of trigger 6 event are 411.rate is 0.161875 Hz. Number of trigger 7 event are 4972.rate is 1.958251 Hz. Number of trigger 8 event are 770.rate is 0.303269 Hz. Number of trigger 9 event are 0.rate is 0.000000 Hz. Number of trigger 10 event are 0.rate is 0.000000 Hz. Number of trigger 11 event are 0.rate is 0.000000 Hz. ******** Scaler Info. ******** T4T5 5129 T4T5TM 210 Mu Matrix 958